HYDROSTATION
Hydrostation is the new IE5 efficiency class electronic system for constant pressure…
Cast iron self-priming centrifugal pump equipped with Venturi unit (ejector and diffuser) in PPE + PS reinforced with glass fibres. Suitable for residential applications. Read more
Flow rate | from 0.3 to 9.6 m³/h |
Total head | from 16.5 to 68 m |
Max. working pressure | 6 bar for AGA 0.60-0.75-1.00 10 bar for the rest of the range |
Max. temperature of the liquid | 45°C |
Max. suction depth | 8 m |
Poles | 2 |
Insulation class | F |
Protection degree | IP44 |
Voltage | Single-phase 1~230V ±10% Three-phase 3~230/400V ±10% |
Pump body | Cast iron |
Impeller | PPE+PS with glass fibres for AGA 0.60-0.75-1.00, brass for the rest of the range |
Shaft | Stainless steel AISI 303 (EN 1.4305) (part in contact with liquid) |
Mechanical seal | Ceramic/Carbon/NBR (standard) |
Motor support | Aluminium for AGA 0.60-0.75-1.00, Cast iron for the rest of the range |
I have fitted a self-priming pump and I have to start it up. Does the pump's body have to be filled with water?
Yes, when it’s first started the pump must always be filled with water and the procedure below has to be followed:
Which is the maximum temperature for the self-priming pump's fluids?
Usually the maximum temperature of the fluid in a self-priming pump should not exceed 45°C.
Some models can handle fluids at higher temperatures. If the requirements differ from the standard please contact our sales network or our Technical Customer Service.
Contact us