Products
EVM
VERTICAL MULTISTAGE ELECTRIC PUMPS

cast iron, AISI 304, AISI 316
Vertical multistage centrifugal electric pumps available in various versions: cast iron (EVMG), AISI 304 stainless steel (EVM), AISI 316 stainless steel (EVML). Suitable for civil, industrial, agricultural and fire-fighting pressure boosting systems, primary water treatment plants, reverse osmosis, seepage, etc., moving moderately aggressive fluids, boiler loading, washing, heating systems and air-conditioning. Reliable, strong, silent and easy to service. The EVM pumps can be coupled with standard EIC motors. They offer state-of-the-art technical solutions. The EVM vertical multistage pumps (hydraulic parts) are in compliance with the 94/9/CE Directive on ATEX products (they belong to Group II, Category 2). Oval counter-flanges, “N” version, already included. Round counter-flanges, “F” version, as accessories.
Version with WRAS approval (EVMW 3-5-10-18). ATEX version for complete electric pump. Also available with efficiency 1 motor.

Specifications

• Maximum working pressure: 16 bar, 25 bar, 30 bar for EVM32 - EVM45 only
• Temperature of the liquid: from -15°C to +120°C; from -15°C to +85°C (for EVMW)

Materials

• Lower pump body, external casing, disco seal housing disc, impellers, nozzles, shaft casing, joint cover and small elements in contact with the liquid in AISI 304 (EVM), AISI 316 (EVML) ["EVMG" version: body in cast iron and hydraulic parts in AISI 304]
• Tie-rods and small elements not in contact with the liquid in galvanised steel
• Shaft in AISI 316
• Bearings in contact with the liquid in tungsten carbide
• Motor support and base in cast iron
• Mechanical seal in SiC/Carbon/FPM (models 3-5-10-18)
• Mechanical seal with cartridge as per standard in SiC/Carbon/FPM (models 32-45-64)
(F= round counter-flanges; N= oval counter-flanges)

Technical document

• Self-ventilated 2 pole asynchronous motor
• Class of insulation F
• IP55 Protection rating
• Single phase voltage 230V ± 10% 50Hz (up to 2.2 kW), three phase voltage 230/400V ±10% 50Hz (up to 4 kW included), three phase voltage 400/690V ±10% (5.5 kW and above)

Total head [m3/h] min 1.20 max 84.00
Total head [m] max 287.00 min 5.70